Fortune® Silicone 2 way Foley balloon Catheter Features:
|
- |
100% medical grade silicone for superior biocompatibility. |
|
- |
Transparent medical grade silicone tube allows easy visual inspection and fluid observation. |
|
- |
X-ray opaque line allows for confirmation of intubated tube using X-ray. |
|
- |
Soft and uniformly inflated balloon makes the tube sit well against the bladder. |
|
- |
Smooth round shaft can minimize trauma during insertion and withdrawal. |
|
- |
6FR, 8FR and 10FR Pediatric Foley Catheter has disposable stylet for easy insertion. |
|
- |
Includes an individual sterilized packed Catheter Spigot. |
|
- |
Sterilized double packaging. |
(A) Pediatric
(B) Standard, 5-10 cc/ml
(C) Standard, 20-30 cc/ml
(D) Female
(E) Catheter Spigot
(F) Tiemann Tip

specifications
2-Way Foley Balloon Catheter, Pediatric:
|
REF. No. |
Size |
Balloon |
Length |
Description |
|
1821-0506 |
6 FR |
1-1.5 cc/ml |
330 mm |
Stylet
X-ray opaque line
Catheter spigot
|
|
1821-0508 |
8 FR |
2-3 cc/ml |
|
1821-0510 |
10 FR |
3-5 cc/ml |

2-Way Foley Balloon Catheter, Standard, 5-10 cc/ml:
|
REF. No. |
Size |
Balloon |
Length |
Description |
|
1822-0512 |
12 FR |
5-10 cc/ml |
420 mm |
X-ray opaque line
Catheter spigot
|
|
1822-0514 |
14 FR |
|
1822-0516 |
16 FR |
|
1822-0518 |
18 FR |
|
1822-0520 |
20 FR |
|
1822-0522 |
22 FR |
|
1822-0524 |
24 FR |
|
1822-0526 |
26 FR |

2-Way Foley Balloon Catheter, Standard, 20-30 cc/ml:
|
REF. No. |
Size |
Balloon |
Length |
Description |
|
1823-0514 |
14 FR |
20-30 cc/ml |
420 mm |
X-ray opaque line
Catheter spigot
|
|
1823-0516 |
16 FR |
|
1823-0518 |
18 FR |
|
1823-0520 |
20 FR |
|
1823-0522 |
22 FR |
|
1823-0524 |
24 FR |
|
1823-0526 |
26 FR
|

2-Way Foley Balloon Catheter, Female:
|
REF. No. |
Size |
Balloon |
Length |
Description |
|
1824-0512 |
12 FR |
5-10 cc/ml |
220 mm |
X-ray opaque line
Catheter Spigot |
|
1824-0514 |
14 FR |
|
1824-0516 |
16 FR |
|
1824-0518 |
18 FR |
|
1824-0520 |
20 FR |
|
1824-0522 |
22 FR |
|
1824-0524 |
24 FR |
|
1824-0526 |
26 FR |

Catheter Spigot:
|
REF. No. |
Size |
Description |
|
1820-0000 |
Universal |
ABS
Sterilized packaging
50 pcs/box |

2-Way Foley Balloon Catheter, Tiemann Tip:
|
REF. No. |
Size |
Balloon |
Length |
Description |
|
1856-0210 |
10 FR |
3-5 cc/ml |
420 mm |
Tiemann tip
X-ray opaque line
Catheter spigot |
|
1856-0212 |
12 FR |
5-10 cc |
|
1856-0214 |
14 FR |
|
1856-0216 |
16 FR |
|
1856-0218 |
18 FR |
|
1856-0220 |
20 FR |
|
1856-0222 |
22 FR |
|
1856-0224 |
24 FR |


Fortune® Silicone 3-Way Foley Catheter Features:
|
- |
100% medical grade silicone for superior biocompatibility. |
|
- |
Transparent tube with X-ray opaque line. |
|
- |
A soft and uniformly inflated balloon makes the tube sit well against the bladder. |
|
- |
3-Way design with an attached plug on the irrigation funnel. |
|
- |
Tapered Central funnel could be connected with irrigation bags. |
|
- |
Includes an individual sterilized packed Catheter Spigot. |
|
- |
Sterilized double packaging. |

specifications
3-Way Foley Balloon Catheter:
|
REF.No. |
Size |
Balloon |
Length |
Description |
|
1830-0514 |
14 FR |
20-30 cc/ml |
420 mm |
Attached plug on flushing port
X-ray opaque line
Catheter spigot
|
|
1830-0516 |
16 FR |
|
1830-0518 |
18 FR |
|
1830-0520 |
20 FR |
|
1830-0522 |
22 FR |
|
1830-0524 |
24 FR |
|
1830-0526 |
26 FR |


Fortune® Foley Integrated Balloon Catheter:
Catheter with Integrated Balloon was designed to minimize the discomfort during catheterization procedure. Compare to the ordinary balloon, due to its thickness, creates a conjunction edge after adhered onto the tubing shaft. This conjunction edge between balloon and shaft will eventually increase patient discomfort during insertion and withdrawal.
Fortune® Integrated Balloon Catheter is invented to eliminate the uneven edge out of ordinary balloon. Patented balloon is integrated into the catheter shaft, creates “complete” smooth surface. No conjunction edge between balloon and shaft is formed, which minimizes the friction within the urethra and reduced patient discomfort.
Advantages:
|
- |
Patented balloon integrated into the shaft. |
|
- |
Complete smooth surface. |
|
- |
Reduce friction within the urethra. |
|
- |
Reduce trauma and secondary harm. |
|
- |
Reduce discomfort during insertion and withdrawal. |
|
- |
Reduce accumulation of urine sediment. |
(A) Silicone Foley Integrated Balloon Catheter
(B) Silicone Foley Integrated Balloon Catheter, Tiemann Tip

specifications
Foley Integrated Balloon Catheter:
|
Cat. No. |
Size |
Balloon |
Length |
Description |
|
4822-0512 |
12FR |
5-10 cc/ml |
420 mm |
Integrated balloon
X-ray opaque line
Catheter spigot
|
|
4822-0514 |
14 FR |
|
4822-0516 |
16 FR |
|
4822-0518 |
18 FR |
|
4822-0520 |
20 FR |
|
4822-0522 |
22 FR |
|
4822-0524 |
24 FR |
|
4822-0526 |
26 FR |
Foley Integrated Balloon Catheter, Tiemann Tip:
|
Cat.No. |
Size |
Balloon |
Length |
Description |
|
4856-0212 |
12 FR |
5-10 cc/ml |
420 mm |
Tiemann tip
Integrated balloon
X-ray opaque line
Catheter spigot
|
|
4856-0214 |
14 FR |
|
4856-0216 |
16 FR |
|
4856-0218 |
18 FR |
|
4856-0220 |
20 FR |
|
4856-0222 |
22 FR |
|
4856-0224 |
24 FR |
|